Stainless Steel Gauze-V4A03/HF+LF Shielding

Due to the thin filaments, use as flyscreen or net curtain, etc


V4A03 is an extremely fine woven, noncorrosive stainless-steel gauze for the protection against high-frequency radiation (HF) and low-frequency electric fields (LF).

In comparision to V4A10, due to the smaller mesh width, the shielding attenuation is better at high frequencies.
Further application in roof areas, at drywall constructions, loosely laid, etc.


V4A (AISI 316) is resistant against water, water vapour, air humidity, mild acids and in coastal areas against salty seawater!

Weight Price
Stainless steel gauze/metres/width 100cmV4A03/100 0.2 kg £10.26
Stainless steel gauze/metres/width 150cm V4A03/150 1 kg £17.90

Technical Specification

Widths: 100 cm or 150 cm
Length: 1 metre, available by the running meter.
You can also order this product in measurements of your choice. For example:- 4.6 linear meters!
This product is cut off a large roll according to customer specifications. A return is not possible!
Attenuation: 55 dB at 1 GHz, two-layers 75 dB
Mesh width: 0.3 mm
Wire diameter: 0.08 mm
Material thickness: 0.16 mm
Open area: 54 %
Weight: 200 g/m².
Colour: Silver.
Fire-proof material: A1 according DIN 4102:1994.
Surface conductivity:0.03 Ohm (square resistance)
Delivery Time: Usually between 2 - 3 working days

Processing
In case processing as flyscreen, the application is identical to that of a regular flyscreen in commercial tenter frames.
In case processing the V4A03 under plaster you should work with a finest organic filler. Under the floor covering (laminate, parquet, PVC coating, etc.) the HEG03 is being fixed with the adhesive used for the floor covering.
For drywall construction and in roof area the mesh elements can be bolted or stapled together.
The rule is: Always overlapp the single elements by at least 5 cm.
For grounding use the perforated stainless steel tape ELB by screwing it right across the elements into the surface.

Grounding
Due to the highly conductive surface this material can be contacted and grounded easy to shield low frequency (LF) electric fields.
For professional grounding we recommend our Grounding Plate Magnet - GM, in combination with Grounding Cable GC-200 Plugged into Grounding Plate Tube-GT/Attach to copper heating Pipes for loose laying application, or our perforated Stainless Steel Tape ELB for application under-plaster or in drywall constructions.

Shielding attenuation
The above mentioned screening attenuation values always apply to 1Ghz. The screening attenuation is regularly tested in our own EMC laboratory, we have measurement setups due to the following standards: ASTM D4935-10, IEEE Std 299-2006, IEEEE Std 1128-1998, ASTM A698/A698M-07. You'll find the PDF test report with further details above on this page.

Customer Reviews

There are currently no reviews of this product.